Minicom Advanced Systems DX System Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Comutadores de rede Minicom Advanced Systems DX System. DX installation guide Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 16
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
International HQ
Jerusalem, Israel
Tel: + 972 2 535 9666
North American HQ
Linden, New Jersey
Tel: + 1 908 4862100
info.usa@minicom.com
European HQ
Dübendorf, Switzerland
Tel: + 41 1 823 8000
info.europe@minicom.com
Italy
Rome
Tel: + 39 06 8209 7902
info.italy@minicom.com
www.minicom.com Customer support - support@minicom.com
5U
M2
0
12
0
V1
5/0
4
DX system
Installation Guide
Rackit
® Technology Corporation
274 Madison Avenue, New York, NY 10016
Tel: (212) 679-0050 Fax: (212) 679-0040
1.800.636.3434
www.RackitTechnology.com
Technology Corporation
®
Supported by:
Vista de página 0
1 2 3 4 5 6 ... 15 16

Resumo do Conteúdo

Página 1 - Installation Guide

International HQ Jerusalem, Israel Tel: + 972 2 535 9666 [email protected] North American HQ Linden, New Jersey Tel: + 1 908 4862100 info.usa@minic

Página 2

DX SYSTEM 9 To Keyboard portCAT5 cable to DX CentralServer portTo Mouse portTo Video cardKeybdMouse100TVideoSerial AParalle lSerial BX-RICC PS/2 Fig

Página 3 - 1. Welcome

INSTALLATION GUIDE 10 To Keyboard PortTo Video CardCAT5 cable to DX CentralServer portX-RICC SUN Figure 9 X-RICC SUN Connecting a X-RICC USB The

Página 4 - 4. System components

DX SYSTEM 11 Connecting a X-RICC RS232 Figure 11 illustrates the connections. To connect the X-RICC RS232: 1. Connect the RS232 connector to the s

Página 5

INSTALLATION GUIDE 12 Insertscrews toconnect torackInsert screws to connectto DX side panelPOWER100-250 VAC 50/60 Hzwww.minicom.comETHERNETSERIALSE

Página 6 - Power Link

DX SYSTEM 13 18. Connecting a KVM switch To connect a KVM switch: 1. Connect a CAT5 cable to the Server port of the DX Central. 2. Connect the ot

Página 7

INSTALLATION GUIDE 14 Connect the Power Tower to the Serial port of the DX Central using the Serial cable provided with the Tower. Connect the Towe

Página 9

DX SYSTEM 1 Table of Contents 1. Welcome ...

Página 10 - Figure 8 PS/2 RICC

INSTALLATION GUIDE 2 1. Welcome The DX system is produced by Minicom Advanced Systems Limited. Technical precautions This equipment generates radi

Página 11 - Figure 10 X-RICC USB

DX SYSTEM 3 2. Introduction The DX system from Minicom is a superior solution for centralized KVM & Serial management. The DX system combines th

Página 12 - Figure 11 X-RICC RS232

INSTALLATION GUIDE 4 • Ethernet cable • Rack mounts for the DX units and the X-RICCs • Minicom Flash USB key 5. Compatibility The DX is compati

Página 13

DX SYSTEM 5 7. The DX Central units Figure 2 illustrates the front panel of the DX 832 Central unit. The DX 432 Central model has the same front pa

Página 14 - 18. Connecting a KVM switch

INSTALLATION GUIDE 6 TO CENTRALPowerconnectorPOWER100-250 VAC 50/60 Hzwww.minicom.comI0KeyboardMouseMonitorComputerKeyboard portComputerMouse portC

Página 15 - 22. Resetting the DX Central

DX SYSTEM 7 Connect a computer to the DX User using the 3 in 1 CPU cable, see Figure 6. 1. Connect the connectors of one end of the 3 in 1 CPU cabl

Página 16

INSTALLATION GUIDE 8 Figure 7 illustrates the DX system connections for a PS/2, SUN USB and RS232 computer/server. KeybdMouse100TVideoSeri al APar